Switchgear Accessories

CTW Spring Operating Mechanism

CTW
CTW spring operating mechanism will be used in XG series SF6 full insulated compact switchgear and other indoor vacuum circuit breaker with equivalent closing power and output rotation angle.
Quantity
Contact Now
add to cart
CTW Spring Operating Mechanism
CTW spring operating mechanism will be used in XG series SF6 full insulated compact switchgear and other indoor vacuum circuit breaker with equivalent
closing power and output rotation angle. Its performances can meet requirements of GB1984 AC High Voltage Circuit Breaker and the product's Technical Conditions;
CTW-S manual operating mechanism holds functions of manual energy-storage; manual closing/opening.
CTW-D motor operating mechanism functions including motor or manual energy-storage; electromagnet or manual closing/opening.
 
Working Condition
 
  • Altitude: ≤2000m
  • Ambient temperature: -25°C~+40°C
  • Relative humidity: Monthly average≤90% (25℃);Daily average≤95% 
  • Vapor data: Monthly average≤1.8kPa; Daily average≤2.2kPa
  • Wind speed: ≤35m/s
  • No operating in such places as subject to explosives, inflammables, corrosives and severe vibration
 
Technical Parameter
 

1.Energy storage motor adopt unidirectional permanent DC motor, technical parameter as Table:

Item

ZYJ220-53-216ZYJ220-53-216ZYJ220-53-216ZYJ220-53-216

Rated operate voltage (V)

DC220DC110DC48DC24

Rated power (W)

40404040

Normal operating voltage range

85%-110%85%-110%85%-110%85%-110%

Rated operating current(A)

0.51.02.34.6

Motor energy storage time (S)

≤8≤8≤8≤8

2.Closing/Opening electromagnet adopt solenoid electromagnet, technical parameter as Table:

Rated operate voltage (V)
AC220AC110DC200DC110DC48DC24
Rated operating current(A)
1.363.60246.713
Rated power (W)
299396440440320320
Coil resistance at 20°C (Ω)
5410.310627.57.22
Normal operating voltage range
Open at 65%~120% rated operate voltage; do not open when less than 30% rated operate voltage
Close at 80%~110% rated operate voltage; do not close when less than 30% rated operate voltage

3.Manual energy storage is operated by the handle allocated with the mechanism, the operating force less than 100 (N.m)

4.Mechanism output angle 43 degree

5.Mechanism net weight: CTW-D: 25kg CTW-S: 20kg

6.The auxiliary switch contacts with the mechanism can pass through continuous current 10A (AC220V) and 3A (DC220V)

7.Limit switch adopt CSK11-A-33 magnetic blowout switch. The continuous current through that the contact can pass: 8A (AC380V); 3A (DC220V)

Outline and installation dimensions

Why Us?
1. Schneider trusted material supplier, you no worry for quality control;
2. STL standard testing lab inside own property factory industrial zone; 
3. 23 years experience of production Medium voltage circuit breaker material, 17 years for overseas market; you no worry for communication and save time.